GT SoftGOT2000
HMI software that allows GOT2000 functions to operate on a personal computer or panel computer.
GT SoftGOT2000
It can be used to monitor and operate the information of industrial devices that are connected to a
personal computer or a panel computer via a network.
- * GT SoftGOT2000 is a software included in GT Works3. A separate license key (GT27-SGTKEY-U)
must be installed during use.
For the details, please contact your local sales office.
operating the information of various industrial devices.
As a remote monitoring tool from your office
- Remote monitoring
Various information of the shop floor can be checked on a personal computer in your office. By making settings with HMI/GOT Screen Design Software GT Works3, necessary information can be checked easily.
As the operation panel of devices
- Convenient operation panel
GT SoftGOT2000 can be used as the operation panel providing operation and monitoring of various industrial devices. In addition, by launching applications compatible with Windows® OS (such as Microsoft® Excel®), the work that you used to do with your computer can be integrated.
Mitsubishi Electric panel computer MI3000 is available for easy setup since GT SoftGOT2000 is pre-installed on the terminal.
As a tool to notify operators of necessary information
- Notify operation status
The resolution can be set flexibly.
By using a large display or a laptop computer, ANDON display and simple remote monitoring can be performed so that operators in a remote location can be notified of the operation status.
Supported resolution
X × Y: 640 to 1920 dots × 480 to 1200 dots
For edge computing purposes
- Simple analysis
GOT Mobile function
With the GOT Mobile function, the equipment status can be checked via on-site GOT or GT SoftGOT2000 using a web browser on information devices from a remote location. Multiple information devices can simultaneously access the GOT or GT SoftGOT2000 so that you can view and operate a different screen on each device.
- * The GOT Mobile Function License is required to use the GOT Mobile function.
Specification comparison
GOT Mobile function server | Number of simultaneous connections from clients | Required license |
---|---|---|
GOT2000 | Maximum 5 | • GOT Mobile Function License for GOT2000 |
GT SoftGOT2000 | Maximum 15 | • License key for GT SoftGOT2000 • GOT Mobile Function License for GT SoftGOT2000 |
Feature
High affinity with GOT2000 Series
Functions equivalent to the GOT2000 Series can be used in GT SoftGOT2000. The project data created with HMI/GOT Screen Design Software GT Works3 can be used by converting it into the GT SoftGOT2000 data.
- For the supported functions, see “Function list”.
GT SoftGOT2000 displays various kinds of documents such as operation manuals*1 of an equipment. You can view PDF files and can instantly check the information you want with bookmark display and keyword searches.
- *1 The document display data should be saved on a virtual drive. PDF files and Document Converter output files (docx, xlsx, pptx, pdf, jpg, bmp) are supported.
GT SoftGOT2000 saves the recipe information (device values) such as material blend and processing conditions. You can change the recipe on the GT SoftGOT2000 and write it to a programmable controller to quickly perform the changeover.
System configurations
GT SoftGOT2000 can be used in single channel connection that monitors one channel and in multi-channel connection that enables monitoring up to four channels of industrial devices. Select the connection type to match your system configuration.
Connectable in all communication types that are supported by GT SoftGOT2000.
[NEW]
Multi-channel connection is supported in Ethernet connection, connection with OPC UA servers, and microcomputer connection only. Up to four channels of industrial devices can be monitored on a single module of GT SoftGOT2000.
Connectable to various industrial devices
Various connection types are supported as follows.*1
Direct CPU connection
Serial communication connection
CC-Link IE Controller Network connection*2
MELSECNET/H, MELSECNET/10 connection*2
MODBUS® /TCP master connection
MODBUS® /TCP slave connection
OPC UA client connection [NEW]
Microcomputer connection (serial) [NEW]
OMRON programmable controller
KEYENCE programmable controller
SIEMENS programmable controller
YASKAWA programmable controller
Yokogawa electric programmable controller
Mitsubishi Electric industrial computer
Robot controller
CNC
RFID/barcode reader
- *1 Supported connection type differs depending on the system configuration (multi-channel connection or single channel connection).
For the details, please refer to the GT SoftGOT2000 Solutions“GT SoftGOT2000 Connectable Model List” on page 22 or the GT SoftGOT2000 Version1 Operating Manual
- *2 A network interface board is required.
Connectable to OPC UA servers [NEW]
GT SoftGOT2000 accesses an OPC UA server as an OPC UA client.*1
- *1 To connect to OPC UA servers, installation of MELSOFT GT OPC UA Client software is required.
To use the OPC UA client connection, use Windows® 7 OS or later.
For more information about how to obtain the software, please contact your local sales office.
Flexible resolution setting
The users can flexibly specify resolutions to change the screen size depending on the information device to use.
GT SoftGOT1000