ANYWIRE DB Master Unit - AV48-01


It connects directly with VME bus.
VME bus master interface


AV48-01


AV48-01 VME bus master interface specification
I/O number 4 all pile mode: 2560 or less Point
(Bit-Bus: 512 points or less/Word-Bus: 2048 or less point)
AnyWireBus port One port and detachable terminal stand
Connected the number 128 or less
Transmission distance The total extension 100m, 200m, 500m, and 1km are selected.
Transmission cycle time Unit[msec] (one cycle time value)
Four-all pile mode bit bus 62.5kHz 31.3kHz 15.6Hz 7.8kHz
64 points 0.85 1.7 3.4 6.8
128 points 1.4 2.7 5.4 10.9
256 points 2.4 4.8 9.5 19.1
512 points 4.4 8.9 17.7 35.5
Four-all pile mode word bus 62.5kHz 31.3kHz 15.6Hz 7.8kHz
IN8word/OUT8word 2.5 5.0 9.9 19.8
IN16word/OUT16word 4.7 9.3 18.6 37.2
IN32word/OUT32word 9.0 18.0 36.0 72.1
IN64word/OUT64word 17.7 35.4 70.8 141.7
RAS function Transmission line disconnection position detection function and transmission line short-circuit detection function
Transmission power supply decrease detection function
Connecting cable Two general-purpose wicks/four wick cable (VCTF 0.75-1.25sq)
Special flat cable (0.75sq) and general-purpose electric wire(0.75~1.25sq)
Power supply +5V±5% 0.4A(supply from VME bus side) DC24V+15--10% ripple 0.5Vp-p or less
About 0.2A or less in current(When 128 in the terminal is connected, the load current is not included. )
Addressing It responds to the short address mode (A16 slave) and AM code 29H and 2DH.
It sets it with dip SW within the range of 0000H-FE00H.
Occupation address 512byte
Width of data D16 slave
Size of card Euro card double size
Ambient temperature of use 0~ +55℃(:-20-+75℃ in preservation temperature)
Use surroundings humidity 10~ 90%RH(dewfall)
Atmosphere Causticity gas and flammability gas

For more details and information, please visit this www.anywire.jp