Ring Blowers
An ideal blower section shape and high-performance silencer greatly reduce operating noise. Forward inclined impeller system enables small size, light weight and high blower pressure.
VFZ Serie
- Unpleasant high-frequency sounds are reduced.
- European RoHS directives (CE marking) are supported in the standard configuration.
- Suction totally-enclosed shutoff operation is supported. [50 & 60 type]
* Note
When using the product in suction totally-enclosed shutoff operation, be sure to remove the emblem from the main body before installation.
- The international protection class is IP54 (motor section).
- Two piping system connection menu is provided (for hose and for phase flange). [10 to 60 type]
- Size and weight are greatly reduced. [70 to 90 type]
Model Variations
Series |
Type |
Voltage (V) |
Frequency (Hz) |
Max. delivery airflow pressure (kPa) |
Max. delivery airflow rate (m3/min) |
50Hz |
60Hz |
50Hz |
60Hz |
Single-phase standard type |
VFZ081PN to 401PN |
100/ |
100 110 |
50/60 |
3.73-9.81 |
4.85-13.2 |
0.47-2.05 |
0.56-2.45 |
Three-phase standard type |
For horse flange |
VFZ081A to 901A |
200/ |
200 220 |
3.73-25.5 |
4.85-31.4 |
0.47-7.5 |
0.56-10.8 |
For companion flange |
VFZ101AF to 601AF |
200/ |
200 220 |
5.15-21.1 |
6.37-27.5 |
0.58-4.2 |
0.69-5.5 |
Three-phase low-noise type |
VFZ101AN to 901AN |
200/ |
200 220 |
5.15-25.5 |
6.37-31.4 |
0.58-7.5 |
0.69-10.8 |
Variable voltage type |
VFZ081A-4Z to 801A-4Z |
380 400 415 |
/ |
400 440 |
3.73-25.5 |
4.85-33.3 |
0.47-6.3 |
0.56-8.5 |
Turbo Blowers
VCP series (High-temperature type)
This series incorporates an efficient heat-resistant design, enabling gas transport at a temperature range from normal to 110°C.
VCT series (Airflow type)
This series incorporates an impeller and a blower made of aluminum alloy, excluding some types. (The impeller of the VCT243A (B) is made of steel. The side plates of the impellers of the VCT263A (B), VCT283A (B), VCT333A (B), and VCT353A (B) are made of steel.
VCS series (High wind pressure, multi-stage type)
A compact multi-stage blower featuring both high wind pressure and airflow volume.
Application examples
VCP series (High-temperature type) |
Dust collection from equipment, forced air cooling, combustion applications, and conveyance equipment. |
VCT series (Airflow type) |
Dust collection from equipment, powder transport, ventilation, exhaust, forced-air cooling, and drying applications. |
VCS series (High wind pressure, multi-stage type) |
Powder transport, forced air cooling, combustion, and conveyance equipment. |
Model Variations
Series |
Type |
Voltage (V) |
Motor output (kW) |
Max. delivery airflow pressure (kPa) |
Max. delivery airflow rate (m3/min) |
VCT (Airflow type) |
VCT243A-393A (50Hz only) |
3φ 200 |
0.75-11 |
2.1-8.0 |
25-70 |
VCT243B-393B (60Hz only) |
0.75-11 |
2.1-8.0 |
25-70 |
VCP (High-temperature type) |
VCP062P |
1φ 100 |
0.18 / 0.31 |
1.1 / 1.6 |
5.5 / 6.5 |
VCP062A |
3φ |
VCP082A |
0.50 / 0.85 |
1.9 / 2.7 |
11 / 13 |
VCS(High wind pressure, multi-stage type) |
VCS402A-702A (50Hz only) |
3φ 200 |
0.75-3.7 |
3.3-14.0 |
8-14 |
VCS402B-702B (60Hz only) |
0.75-3.7 |
3.3-15.0 |
13-16 |
|
|