Pro-face Remote HMI
Synchronous and Asynchronous Operation Mode
The Pro-face Remote HMI supports synchronous and asynchronous operation modes which switch during operation.
A new parameter in the GP-Pro EX setting provides the option to limit the operation modes for the Pro-face Remote HMI.
A new parameter in the GP-Pro EX setting provides the option to limit the operation modes for the Pro-face Remote HMI.
*In the synchronous operation mode, the HMI and the Pro-face Remote HMI always display the same screen.
In the asynchronous operation mode both devices can show different screens and allow independent operation.
In the asynchronous operation mode both devices can show different screens and allow independent operation.
Alarm Monitor Function
Indicating the status of each HMI in the overview reduces the time for identifying the faulty system and further reduces the downtime and associated costs. Besides the status bar for each HMI, any alarm can also trigger an alarm sound.
*The Alarm Monitor Function is supported by GP-Pro EX Ver. 4.0 or later.
Auto Start
As soon as the power is turned on, it indicates User-specified display, right from start-up.
Able to display an alarm message on the Notification center
While you are displaying and operating a screen of the currently connected device on your tablet or smartphone, if an alarm is triggered on another device, you can immediately notice it. Swipe down the notifications and tap the ‘Pro-face Remote HMI’ alarm message in order to switch to the screen of the device with the alarm triggered, and you will be able to immediately respond to the alarm.
* This Function is supported by GP-Pro EX Ver. 4.03 or later.
* iOS is not supported.
* iOS is not supported.
Exclusive Touch Operation
Setting the monopolize touch function prevents unexpected operational misuses caused by redundant operation.
You can set a touch monopoly time, or set an arbitrary address for a control address to intentionally monopolize touch operation.
You can set a touch monopoly time, or set an arbitrary address for a control address to intentionally monopolize touch operation.
Remote Status Icon
A local operator can check the status of remote connection and touch monopoly of HMI server or remote client on a HMI screen for operation safety.
Blank: Connected
S: HMI Server monopolized
C: Mobile Client monopolized
S: HMI Server monopolized
C: Mobile Client monopolized
Pro-face Remote HMI Server
Connect to standard Windows-based systems
By installing Pro-face Remote HMI Server on any PC or IPC, you can use Pro-face Remote HMI to monitor and operate and monitor windows applications such as Excel and PDF.
* Pro-face Remote HMI Server is a Windows application to connect any PC or IPC with our Pro-face Remote HMI application and operate any kind of software via the application.
Application
Monitoring Anywhere of Large/Long Equipment
Using the remote monitoring and operation functions, actions that previously required multiple staff for a large-sized machine or long-distance application can be easily accomplished by fewer operators.
* Please check equipment status and maintain conditions for machine safety to avoid unintended equipment operation.