SPECIFICATION
Lineup | FX5U (Screw terminal type): 12 models FX5UC (Connector type): 6 models FX5UC (Spring clamp terminal type): 2 models |
Control method | Stored program cyclic operation |
I/O control mode | Refresh mode |
Programming language | Ladder diagram Structured text (ST) Function block diagram (FBD/LD) Function block (FB) |
Engineering environment | MELSOFT GX Works3 |
Program size (K step) | 64 |
Number of I/O points [X/Y] (point) | 256 |
Device/label memory/ standard RAM (K byte) | 120 |
Data memory/ standard ROM (byte) | 5 M |
Processing speed | |
LD instruction (ns) | 34 |
MOV instruction (ns) | 34 |
Floating point addition (µs) | 3.06 |
Memory interface | |
Extended SRAM cassette | — |
SD memory card | ● |
SRAM card, FLASH card, ATA card | — |
External interface | |
USB | — |
Ethernet (1000BASE-T*7/ 100BASE-TX/ 10BASE-T) |
● |
RS-232 | — |
RS-422/485 | ● |
Display unit | — |
CC-Link IE connection port | |
Ethernet (1000BASE-T/ 100BASE-TX/ 10BASE-T) |
— |
Network connectivity (adapter/module) | |
Ethernet (1000BASE-T*13/ 100BASE-TX/ 10BASE-T) |
● |
CC-Link IE Control | — |
CC-Link IE Field | ● |
CC-Link | ● |
CC-Link/LT | — |
SSCNET Ⅲ/H | ● |
AnyWire | ● |
BACnet™ | — |
MODBUS®/TCP | ● |
MODBUS® | ● |
General specifications/conformed standards | |
Operating ambient temperature | 0…55℃*20 |
International safety standards (ISO 13849-1 PL e, IEC 61508 SIL 3) |
— |
Standard on corrosive atmosphere (JIS C60721-3-3/ IEC60721-3-3 3C2) |
— |
CE: Council Directive of the European Communities | ● |
UL: Underwriters Laboratories Listing | ● |
LR: Lloyd’s Register of Shipping approval | — |
DNV: Norwegian Maritime approval | — |
RINA: Italian Maritime approval | — |
NK: ClassNK approval | — |
ABS: American Bureau of Shipping approval | — |
BV: Bureau Veritas approval | — |
GL: Germanischer Lloyd approval | — |
Key features/functions | Machine control Distributed control Small-scale I/O control Space/cost saving Security Integrated network Extensive built-in functions Data logging Motion control |
*1: Supports redundant system when paired with R6RFM
*2: SFC is not supported in redundant mode and by safety CPU
*3: Q□UDVCPU only
*4: When using CW Workbench
*5: Does not support QnUDVCPU and certain models
*6: Does not support L02SCPU(-P)
*7: Supports the user Ethernet port of Q24DHCCPU-V/VG/LS and Q26DHCCPU-LS only
*8: Supports Q□UDE(H)CPU and Q□UDVCPU only
*9: Does not support Q□UDE(H)CPU and Q□UDVCPU
*10: Supports L02SCPU(-P) only
*11: Supports FX3G only
*12: R□ENCPU only
*13: Supports the MELSEC iQ-R Series only.
*14: Supported by expansion board
*15: Does not support Q□(P)(H)CPU and Q□PRHCPU
*16: Supports SSCNET Ⅲ
*17: Only supported when used together with extended temperature range main/extension base units
*18: R□SFCPU-SET only.
*19: For protection against aggressive atmosphere and gases, products with a conformal coating (JIS C 60721-3-3/IEC 60721-3-3 Class 3C2) are available on request
*20: Operating ambient temperature from -20℃ is supported by products produced from June 2016 (serial number “166” or later). For details, on supported products, please refer to the relevant product manual.