Available in pump and metered versions for all spray technologies, ProMix 2KE makes plural component finishing EASY. Designed for multi-color, two component, in-booth applications.
Graco has specific ProMix proportioners that are designed to manage tough acid catalyst applications like cabinetry and bar counter tops. The corrosion resistance fluid section, plus the smart fluid plate with 316 and 17-4 SST catalyst sections, can easily handle strong acid catalysts.
Features :
- Designed for multi-color, two component, in-booth applications
- Choose between pump-based or meter-based plural component systems
- Stay on ratio within predefined tolerance limits, down to ±1% with the meter version and ±2% with the pump version
- Off-ratio material will not reach your product – eliminating expensive re-work
- Easy to service cartridge style fluid valves
- Ability to program maintenance reminders
LCD Display
- Mounts up to 10 feet away with standard cable
- Simple operation functions: standby, spray, purge and flushing
- Displays mix ratio, pot life time(s), and material flow rate
- Easy to change colors on meter units
- Material use screen for tracking costs and creating environmental reports
- Settable maintenance reminders: pump cycles, valve cycles and filter days
Specifications :
ProMix 2KE Meter-Based System | |
Maximum fluid working pressure |
275.8 bar, 27.58 MPa
|
Maximum working air pressure |
7.0 bar, 0.7 MPa
|
Air supply |
5.2–7.0 bar, 0.5–0.7 MPa
|
Air filter inlet size |
3/8 npt(f)
|
Air filtration for air logic (Graco-supplied) |
5 micron (minimum) filtration required; clean and dry air
|
Air filtration for atomizing air (user-supplied) |
30 micron (minimum) filtration required; clean and dry air
|
Mixing ratio range |
0.1:1–30.0:1
|
On-ratio accuracy |
up to +/- 1%, user selectable
|
Fluids handled |
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes
|
Fluid inlet sizes |
1/4 npt(f)
|
Fluid outlet size (static mixer) |
1/4 npt(f)
|
External power supply requirements |
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
|
Operating temperature range |
5–50°C
|
Approximate Weight |
91 kg
|
Environmental conditions rating |
indoor use, pollution degree (2), installation category II
|
Wetted parts |
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
|
Fluid Flow Rate Range | |
G3000, G250 Meter |
75–3800 cc/min
|
G3000HR, G250HR Meter |
38–1900 cc/min
|
Coriolis Meter |
20–3800 cc/min
|
S3000 Solvent Meter (accessory) |
38–1900 cc/min
|
Noise Level | |
Sound pressure level |
below 70 dBA
|
Sound power level |
below 85 dBA
|
ProMix 2KE | |
Maximum fluid working pressure |
See Manual 3A0868.
|
Maximum working air pressure |
0.7 MPa, 7 bar
|
Air supply |
0.5 to 0.7 MPa, 5.2 to 7 bar
|
Air filter inlet size |
3/8 npt(f)
|
Air filtration for air logic (Graco-supplied) |
5 micron (minimum) filtration required; clean and dry air
|
Air filtration for atomizing air (user-supplied) |
30 micron (minimum) filtration required; clean and dry air
|
Mixing ratio range |
0.1:1 to 30:1
|
Viscosity range of fluid |
20 to 5000 cps
|
Fluid filtration (user-supplied) |
100 mesh minimum
|
Fluid outlet size (static mixer) |
1/4 npt(f)
|
External power supply requirements |
85 – 250 Vac, 50/60 Hz, 2 amps maximum draw. 15 amp maximum circuit breaker required. 8 to 14 AWG power supply wire gauge
|
Operating temperature range |
5° to 50°C
|
Approximate weight |
136 kg
|
Environmental conditions rating |
indoor use, pollution degree (2), installation category II
|
Fluids handled |
one or two component:solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
|
On-ratio accuracy | |
1:1 to 10:1 Mixing Ratio |
± 2%
|
10.1:1 to 30:1 Mixing Ratio |
± 5%
|
Noise level | |
Sound pressure level |
below 70 dBA
|
Sound power level |
Below 85 dBA
|
Materials of construction | |
Wetted materials on all models |
303, 304 SST; Tungsten carbide (with nickel binder);perfluoroelastomer; PTFE
|
ProMix 2KE Pump-Based System | |
Maximum fluid working pressure |
See the ProMix 2KE manual.
|
Maximum working air pressure |
7.0 bar, 0.7 MPa
|
Air supply |
5.2–7.0 bar, 0.5–0.7 MPa
|
Air filter inlet size |
3/8 npt(f)
|
Air filtration for air logic (Graco-supplied) |
5 micron (minimum) filtration required; clean and dry air
|
Air filtration for atomizing air (user-supplied) |
30 micron (minimum) filtration required; clean and dry air
|
Mixing ratio range |
0.1:1–30:1
|
On-ratio accuracy |
1:1 to 10:1 Mixing Ratios: +/- 2%, 10:1 to 30:1 Mixing Ratios: +/- 5%
|
Fluids handled |
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
|
Viscosity range of fluid |
20–5000 cps
|
Fluid filtration (user-supplied) |
100 mesh minimum
|
Fluid outlet size (static mixer) |
1/4 npt(f)
|
External power supply requirements |
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
|
Operating temperature range |
5–50°C
|
Approximate Weight |
136 kg
|
Environmental conditions rating |
indoor use, pollution degree (2), installation category II
|
Wetted parts |
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
|
Noise Level | |
Sound pressure level |
below 70 dBA
|
Sound power level |
below 85 dBA
|
ProMix® 2KE | |
Maximum fluid working pressure |
See Hazardous Location Models in manual 3A0870
|
Maximum working air pressure |
7 bar , 0.7 MPa
|
Air supply |
5.2 – 7 bar, 0.5 – 0.7 MPa
|
Air filter inlet size |
3/8 npt(f)
|
Air filtration for air logic (Graco-supplied) |
5 micron (minimum) filtration required; clean and dry air
|
Air filtration for atomizing air (user-supplied) |
30 micron (minimum) filtration required; clean and dry air
|
Mixing ratio range |
0.1:1- 30:1
|
On-ratio accuracy |
up to ±1%, user selectable
|
Fluids handled | |
one or two component: |
solvent and waterborne paints
|
polyurethanes | |
epoxies | |
acid catalyzed varnishes | |
moisture sensitive isocyanates | |
Viscosity range of fluid |
20- 5000 cps
|
Fluid filtration (user-supplied) |
100 mesh minimum
|
Fluid flow rate range | |
G3000, G250 Meter |
75 – 3800 cc/min.
|
G3000HR, G250HR Meter |
38 – 1900 cc/min.
|
Coriolis Meter |
20 – 3800 cc/min.
|
S3000 Solvent Meter (accessory) |
38 – 1900 cc/min.
|
Fluid inlet sizes | |
Flow Meter |
1/4 npt(f)
|
Dose Valve/Color Valve Adapters |
1/4 npt(f)
|
Fluid outlet size (static mixer) |
1/4 npt(f)
|
External Power Supply Requirements | |
85 15 amp maximum circuit breaker required-
|
|
250 Vac, 50/60 Hz, 2 amps maximum draw
|
|
8 to 14 AWG power supply wire gauge | |
Operating temperature range |
5-50° C
|
Approximate Weight | |
Meter Systems |
91 kg
|
Pump Systems |
136 kg
|
Environmental Conditions Rating |
indoor use, pollution degree (2), installation category II
|
Noise Level | |
Sound pressure level |
below 70 dBA
|
Sound power level |
below 85 dBA
|
Wetted parts |
303, 304 SST, Tungsten carbide (with nickel binder), perfluoroelastomer; PTFE
|