ANYWIRE Open Terminal - AB023-C1


Open network CC-Link
Subdivision scatter making.


AB023-C1


AB023-C1 CC-Link Bit decentralization I/O terminal specification

Main body specification
I/O number 1-512 Point(IN256+OUT256)
Conserve wiring port One port
The terminal connection number 128 or less
Conserve wiring connection distance The total extension maximum 50m
Conserve wiring transmission cycle time
(one cycle time value)
1.7 Ms/64 point, 2.7ms/128 point, 4.8ms/256 point, and 8.9ms/512 point
Conserve wiring connection cable Two general-purpose wicks(VCTF 0.75~1.25sq)
Two general-purpose electric wire wicks(0.75~1.25sq)
Power supply DC24V+15--10% ripple 0.5Vp-p or less
About 0.4A or less in current(When 128 in the terminal is connected, the load current is not included. )
Ambient temperature of use 0~+55℃(:-20-+75℃ in preservation temperature)
Use surroundings humidity 10-90%RH   dewfall
Atmosphere Causticity gas   flammability gas
Externals size[mm] 40×100×66(It doesn't contain the projection part. )


CC-Link interface specification
Version CC -Li nk Ver .1.10
Transmission rate 10M/5M/2.5M/625K/156Kbps (switch selection)
Communication method Broadcast polling method
Synchro system Frame synchronous communication
Encoding method NRZI
Transmission line form Bus form(EIA RS485 conforming)
Transmission format HDLC conforming
Connected the number (1 ×a )+ (3 ×c ) + (2 ×b ) + game of (4 ×d ) ≦64
The number of a :1 game occupation bureau, the number of b :2 game occupation bureau, the number of c :3 game occupation bureau, and the number of d :4 game occupation bureau
16 ×A +54 ×B +88 ×C ≦2304
A: Remote I/O bureau 64 or less ..number ・・・・・・・・・・・・・・・・・..
B: Remote device bureau 42 or less ..number ・・・・・・・・・・・・..
C: Local bureau 26 or less ..number ・・・・・・・・・・・・・・・・・・・・・..
Remote exchange number Exchange number setting range 1 -64(one exchange number setting)
Power supply CRC (X 16 +X 12 +X 5 +1 )
RAS function Automatic [fukuretsu] function
Child bureau separation function
Confirmation of state of data link
Off-line test(hardware test, line test, and parameter confirmation test)
Connecting cable Cable for CC -Link(3 with shield wick twisted-pair cable)
Number of occupation bureaux Remote device bureau 1-4 Game(switch selection)

For more details and information, please visit this www.anywire.jp